Ningbo Suntech Power Machinery Tools Co.,Ltd.

Ningbo Suntech Power Machinery Tools Co., Ltd. Professional Manufacturer and Exporter of Electric Power Field

Manufacturer from China
Verified Supplier
5 Years
Home / Products / High Voltage Cable Testing Equipment /

45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation Test

Contact Now
Ningbo Suntech Power Machinery Tools Co.,Ltd.
Visit Website
City:ningbo
Province/State:zhejiang
Country/Region:china
Contact Person:MrPeter Mao
Contact Now

45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation Test

Ask Latest Price
Video Channel
Brand Name :Ningbo Suntech Power
Model Number :CHX-270KVA/45KV,270KV
Certification :ISO9001
Place of Origin :Ningbo,China
MOQ :One Unit
Price :Negotiable
Payment Terms :T/T
Supply Ability :10units/2months
Delivery Time :25~45 Work Days
Packaging Details :Export Standard Wooden Case With Fumigation Free
Test Principle :Variable Frequency Resonant Circuit
Test Item :AC Withstand Voltage Test Under 45KV , 270KV
Max.capacity :270KVA
Max. Voltage :45KV , 270KV
Design Feature :Portable Type , Lighter Single Piece Weight, Special For On-site Installation And Test
Component :V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider
Test Frequency :30-300Hz
Duty Cycle :60 Mints
Test Accuracy :No Less Than 1.5%
Output Waveform :Good Sine Wave
Test Object :35KV/10KV Short Cable , 110KV Power Substation
Test Standard :IEC 60060-1:2010;IEC 62271-203:2011 For GIS, IEC 60840:2011 For XLPE Cable;
High Light :high voltage resonant test system, resonant test set
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Portable Variable Frequency Resonant Withstand Voltage Test Set , For 35KV Cable and 110KV Power Substation Test

I. Product Usage :

This test set model CHX-270KVA/45KV, 270KV is designed for 10KV / 35KV class short XLPE cable ,power transformer, CB,CT/PT, busbar in 110KV power substation to perform on-site AC withstand voltage test with variable frequency resonant circuit technology; the highest test voltage is no more than 45KV ,90KV,270KV; test frequency: 30-300Hz; the duty cycle is no more than 60mints. it can help customers to perform preventive test or hand-over test on AC withstand voltage test

Test range of the set is as following:transformer

1. 1000m of 35kV/300mm2 cable, test frequency 30-300Hz, test voltage 52kV, test time 5min.

2, 3000m of 10kV/300mm2 cable , test frequency 30-300Hz, test voltage 22kV, test time 5min.

3, 35kV/31500kVA main transformer , capacitance ≤ 0.015uF, test frequency 40-300Hz, test voltage 68kV, test time 1min.

4, 110kV/50000kVA main transformer , capacitance ≤ 0.015uF, test frequency 40-300Hz, test voltage 160kV, test time 1min.

4, CB,CT/PT, busbar in 110KV power substation , test frequency 40-300Hz, test voltage no more than 265, test time 1min.

The whole test set consists of variable frequency power source , excitation transformer , 6pieces of reactors, and high voltage measurement devider(capacitive voltage divider). This type of test set is most suitable for 35KV or 110KV power sub-station

II. General Technical Data

  1. Rated capacity: 270kVA;
  2. Input power: three-phase 380V voltage, frequency is 50Hz;
  3. Rated voltage: 45KV; 270kV;
  4. Rated current: 1A; 6A;
  5. Working frequency: 30-300Hz;
  6. Device output waveform: sine wave
  7. Waveform distortion rate: output voltage waveform distortion rate ≤ 1%;
  8. Working time: continuous 60min allowed under rated load; overpressure 1.1 times 1 minute;
  9. Temperature rise: temperature rise ≤65K after continuous operation for 60 minutes under rated load;
  10. Quality factor: device itself Q≥30 (f=45Hz);
  11. Protection function: Over-current, over-voltage and test product flashover protection for the tested product (see the variable frequency power supply section for details);
  12. Measurement accuracy: system effective value 1.5;


III. Main Components:

SN Name of Components Type and specification Qty. Each weight Each Dimension
1 Variable frequency power FKVF-20kW/380V 1piece 35kgs 480*480*520mm
2 Excitation transformer CQSB(J)-15kVA/2.5KV,10KV 1piece 130kgs 500*500*580mm
3 HV resonant test reactor CHX(kf)-45kVA/45kV 6pieces 55kgs D420*H480mm
4 Capacitive divider TRF-270kV/1000pF 1set 30kgs D200*H2150mm
5 Special test accessories 1set

IV. Test priciple :
45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation Test

VF: Variable Frequency Power Source T : Excitation Transformer
L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm )


V. Main Measuring and control software panel:
45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation Test
Note: This is the software panel before start test for parameter setting


VI.Accessories

  • Accessory box for storage accessoires
  • Input cables of power source
  • Output cables of power source
  • Output cables of exciting transformer
  • System grounding cables
  • Parallel cables of the reactor
  • HV measuring cables ( the signal output cables of voltage divider )
  • HV output cables(reactor to divide,divider to test object)
  • Insulation supporting base
  • corona ring for 135KV test
  • A final test report, a quality Certificate ,a user manual and a packing list are offered .


VII. Other Optional Model

1. For GIS on-site test

Model Rated voltage Rated output current Rated output capacity

Application

(From 45Hz starting)

CHX-135KVA/135KV 27KV*5 1A 135KVA For 72.5KV and below GIS
CHX-270KVA/135KV 27KV*5 1A 135KVA For 72.5KV and below GIS
CHX-216KVA/216KV 27KV*8 1A 216KVA For 123KV and below GIS
CHX-270KVA/270KV 27KV*10 1A 270KVA For 145KV and below GIS
CHX-275KVA/275KV 275KV 2A 275KVA For 170KV and below GIS
Special requirement can be made by order

2. For 45KV XLPE cable on-site test

Model Rated voltage Rated output current Rated output capacity Max Application
CHX-108/54 54KV 2A 108KVA 45kV cable≤1km
CHX-216/54 54KV 4A 216KVA 45kV cable≤2km
CHX-324/54 54KV 6A 324KVA 45kV cable≤3km
CHX-432/54 54KV 8A 432KVA 45kV cable≤4km
CHX-540/54 54KV 10A 540KVA 45kV cable≤5km
CHX-1080/54 54KV 20A 1080KVA 45kV cable≤10km
Special requirement can be made by order

3. For 66KV XLPE cable on-site test

Model Rated voltage Rated output current Rated output capacity Max Application
CHX-160/80 80KV 2A 160KVA 66kV cable≤0.5km
CHX-320/80 80KV 4A 320KVA 66kV cable≤1km
CHX-640/80 80KV 8A 640KVA 66kV cable≤2km
CHX-960/80 80KV 12A 960KVA 66kV cable≤3km
CHX-1280/80 80KV 16A 1280KVA 66kV cable≤4km
CHX-1600/80 80KV 20A 1600KVA 66kV cable≤5km
CHX-3200/80 80KV 40A 3200KVA 66kV cable≤10km
CHX-9600/80 80KV 120A 9600KVA 66kV cable≤20km
Special requirement can be made by order

VIII. On-site insulation test standard table from IEC 60840:2011 for XLPE cable

45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation Test

Inquiry Cart 0